Furman CN-15MP MiniPort
SKU: FUR-CN-15MP
MPN: CN-15MP
Description
2-Outlet Power Controller 15A SmartSequencing Voltage Protection Bi-Directional Communication
Send to a friend!
SKU: FUR-CN-15MP
MPN: CN-15MP
2-Outlet Power Controller 15A SmartSequencing Voltage Protection Bi-Directional Communication
Send to a friend!
CN-15MP MiniPort
The Furman Contractor Series CN-15MP MiniPort is the definitive solution for providing remote AC power control to equipment located away from the main system rack, such as powered speakers. Engineered with Furman's SmartSequencing technology, this unit allows multiple MiniPorts to be daisy-chained over runs e 1,000 feet apart, with bi-directional communication for reliable sequencing of large and complex systems. It offers a 15 Amp capacity with a thermal breaker and features two NEMA 5-15R outlets. For ultimate equipment safety, the CN-15MP includes Extreme Voltage Shutdown (EVS), which protects against sustained under-voltage (below 80V) or over-voltage (over 145V) events. Sequencing can be initiated remotely via standard analog triggers or a digital link from a CN-1800S or CN-2400S, providing maximum installation flexibility for any commercial AV system.
Contractor Series MiniPorts extend the benefits of SmartSequencing to electronics outside of the equipment rack, providing tremendous flexibility to any installation scenario. Units may be daisy-chained and fully controlled via a Furman SmartSequencer, legacy Furman sequencer, third-party sequencers, and/or control and automation systems.
DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches.
Sequencing of duplex initiated remotely by standard analog triggering (remote terminal) or digital link (SmartSequencing from CN-1800S or CN-2400S).
The CN-15MP can shut itself off automatically when triggered by a fire alarm.
15
Furman Sound
SmartSequencing™
SmartSequencing allows bidirectional, safe sequenced power up/down operations via the push of a button or turn of a key
Voltage Protection
Extreme Voltage Shutdown (EVS) safeguards from catastrophic under-voltage (under 80V sustained) or over-voltage (over 145V sustained) conditions. The EVS feature can be selectively enabled or disabled according to the preference of the user
Diagnostic Lights
Diagnostic lights provide valuable system information including power quality
15 Amp Output Current
15 amp maximum current capacity with incorporated 15 amp thermal circuit breaker
DIP Switch Customization
DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches